Cirrus-logic EP93xx Uživatelský manuál Strana 637

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 824
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 636
DS785UM1 18-3
Copyright 2007 Cirrus Logic
Timers
EP93xx User’s Guide
1
8
1
8
Register Descriptions
Timer1Load,
Timer2Load
Address:
Timer1 - 0x8081_0000 - Read/Write
Timer2 - 0x8081_0020 - Read/Write
Reset Value:
0x0000_0000
Definition:
The Load register contains the initial value of the timer and is also used as the
reload value in periodic timer mode. The timer is loaded by writing to the Load
register when the timer is disabled. The Timer Value register is updated with
the Timer Load value as soon as the Timer Load register is written. The Load
register should not be written after the Timer is enabled because this causes
the Timer Value register to be updated with an undetermined value.
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
Load: Initial load value of the timer.
Timer3Load
Address:
Timer3 - 0x8081_0080 - Read/Write
Reset Value:
0x0000_0000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
Load
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Load
1514131211109876543210
Load